Product Highlights
- Up to 512 Mbps sustained data transfer rate.
- Up to 90.1GB of storage internally.
- Generic parallel ECL or Fibre Channel user equipment interfaces.
- High-speed digital cassette tape recorder emulation for DCRsi, VLDS and ID-1.
- Full-duplex user equipment data ports support simultaneous read and write.
- Read-after-write with re-write error detection and correction.
- MONSSTR recorders may be daisy chained for increased capacity.
- Extensive built-in-test, diagnostic and status reporting software.
MONSSTR Recorders
Harsh environments encountered in many military and aerospace programs often preclude the use of magnetic tape or disk for instrumentation data recording. Furthermore, today's ever-increasing demands for higher data recording rates often exceed the capability of magnetic recording technology. The CALCULEX MOdular Non-volatile Selectable STorage Recorder (MONSSTR) overcomes all of the limitations associated with magnetic recording technology by utilizing high-density, non-volatile flash memory in an innovative system architecture enclosed in modular rugged packaging. Featuring sustained data rates up to one gigabit per second, storage capacities over 90 gigabytes, and a wealth of features only possible with solid-state, random-access devices, MONSSTR is the answer to the stringent requirements of the next generation of instrumentation data recorders.
System Architecture
Model 5000 recorders accommodate one controller plus an optional multiplexer board and contain fixed, non-removable memory.
Power modules are available for use with AC or DC power sources. Standard power modules for ruggedized CSR-5000 is 115VAC/400Hz and 28VDC.
Storage Capacities
Model 5000 MONSSTR recorders do not utilize removable canisters. Model 5000 recorders contain up to 90 gigabytes of non-removable memory.
Data Rates
The maximum sustained data rate of a MONSSTR recorder is determined by the speed of the internal bus, the mode of operation and the I/O controllers installed. Model 5000 busses are capable of sustained data rates of up to 64 megabytes per second.
The user equipment interface data transfer rate of a MONSSTR recorder may not always be equal to the maximum data rate of the internal bus. If one controller is active and operating in basic read or write mode, the maximum user interface transfer rate will be equal to the maximum sustained data rate of the internal bus or the user equipment, whichever is less. However, if the controller is operating in record mode with read-after write enabled, the maximum net throughput will be one-half of the maximum data rate of the internal bus.
I/O Controllers
MONSSTR I/O controller design is organized into three "layers" of internal hardware and firmware: a physical layer, a logical layer and virtual layer. The physical layer interfaces to the system bus and performs basic memory read and write operations. The logical layer performs error detection and correction operations and memory management. The virtual layer defines the personality of the controller for the user equipment interface. All MONSSTR I/O controllers are identical at the physical and logical layers. However, different controller models have different virtual layer firmware and hardware to accommodate a variety of user equipment data communication protocols.
CSR-5121 Controllers
These controllers feature a generic parallel I/O user equipment interface with maximum data transfer rates equal to that of the internal system bus. The user equipment interface is either differential ECL or differential PECL, and may be configured for 8-bit (all models) or 16-bit (6000) parallel data transfers. Onboard time code reader/generators are used to append time stamps to user data. Host control is asserted by means of a serial control port that may be Configured for standard RS-232 or RS-422 operation.
CSR-5123 Controllers
These controllers emulate the Ampex DCRsi tape recorder. Data rates of up to 64 megabytes per second are attainable across the user equipment interface. In read-after-write mode, up to 128 megabytes per second of internal bus bandwidth is used (64 MB/s write and 64 MB/s read).
CSR-5124 Controllers
These controllers feature ANSI Standard Fibre Channel fiber optic interfaces. Bit-serial I/O is supported at user equipment data transfer rates equal to that of the internal system bus on the Model 5000 version. The user equipment interface features ANSI standard Fibre Channel hardware. On-board IRIG time code reader/generators are used to append time stamps to user data. No separate control port is necessary; system control is asserted via the Fibre Channel interface.
CSR-5125 Controllers
These controllers feature Enertec ID-1 emulation. This interface is based on 8-bit ECL logic and supports the interface protocol for ID-1 tape recorders. Host control is accomplished through a separate serial connection.
CSR-5032 Multiplexer
The CSR-5032 packet multiplexer with two PCM channels, two 1553 channels, one time code channel and one voice channel may be installed in the multiplexer slot of a Model 5000 MONSSTR.
Read-After-Write
All MONSSTR controllers incorporate data buffer memory that preserves user input data until it has been successfully stored in the memory canister. When read after-write mode is enabled, the controller will read each data word after it is written to verify that it was written correctly. This feature may be enabled or disabled by the user equipment. Since two bus transfers are required for each word recorded in this mode of operation, the maximum net throughput is limited to one-half of the maximum internal bus data rate of the MONSSTR recorder.
Special Memory Operations
Special memory operations may be enabled or disabled by the user equipment. Enabling erase-before-write mode allows the MONSSTR recorder to operate in circular buffer mode. Once the memory is filled, oldest data is erased and re-written with new data. A daisy chain mode allows multiple MONSSTR recorders to be connected together such that when the memory in one is full, the next one in the chain will begin recording.
Momentary Power Outages
MONSSTR power modules incorporate sufficient capacitance to support full-up operation of the recorder during power losses of up to 50 milliseconds. Loss of power for more than 50 milliseconds will result in a clean power-down sequence with no loss of previously recorded data.
| SPECIFICATIONS CSR-5000 | |
| Model | CSR-5000 |
| Capacity: | Up to 90.1GB |
| Size (Inches): | 4.5 x 4.9 x 12.1 |
| Weight (Pounds): | Up to 18 |
| Bandwidth: | 512Mbps |
| Maximum Power: | 2.0 Amp @ 28VDC, Per MIL-STD-704A/D |